The exit device is suitable for all doors aluminum hollow metal or wood where there is no projection on the face.
Panic device for double doors.
No matter the application yale s range of exit devices is sure to suit your door.
The inactive side is then secured by a vertical rod exit device which latches at the top of the door frame and into the threshold.
The 2 devices are most commonly used in.
Panic hardware is installed and used on doors as an exit device.
International building code ibc only requires this type of hardware on buildings.
Panic hardware used on balanced doors must be touchpad type and the touchpad must not extend more than half the width of the door measured from the latch side.
The active door of the pair is typically prepped for a locking device such as a lockset or exit device.
For rim panic devices the strike plate is mounted on the door frame a mullion for double doors or the inactive door for double doors without a center mullion.
With specific high traffic or high hazard occupancy such as educational or assembly facilities with more than.
The global door controls th1100edtbarf fire rated touch panic the global door controls th1100edtbarf fire rated touch panic bar is 36 in.
The inactive door or fixed door is prepped for flush bolts top and bottom and includes an astragal which covers or closes the gap between the edges of the doors.
Alarmed exit hardware featuring a rugged construction designed for functioning reliability sargent alarmed exit hardware uses both audio and visual indicators to signal and.
Doors serving electrical rooms with equipment rated 1 200 amperes or more and over 6 feet wide that contain overcurrent devices switching devices or control devices with exit access.
When a set of double doors has both a vertical rod exit device and a rim exit device the rim exit device strike is mounted to the normally inactive side of the double doors.
Offered with four available functions the heavy duty 20 series features a rugged design of angled covers and a tapered push rail that fully extends across the door.
Understanding code requirements for panic hardware.
It is usually only installed on doors that are required by law to have panic hardware.
Trusted brands including von duprin falcon precision dormakaba sargent and yale.
Exit devices or push pull hardware is required to make both doors active.
The special von duprin 2 door device as of 02 07 14 is now shipped with ul panic hardware label or ul fire exit hardware label.
It is the most common type of exit device since it is the easiest to install especially on existing single doors.
7000 series architectural exit devices.
A rim panic device is surface mounted on the door with the latch projecting from the panic device rather than the door edge.
The 2 devices are most commonly used in.